Rotary table PSR-325TJ
Planar ServoRing rotary tables provide superior angular positioning and are designed to eliminate backlash, friction and wear problems associated with worm, gear and belt drives. Low maintenance and high throughput characteristics of the AccuRing stage yields the lowest total cost of ownership.
Compact package and Superior design of the AccuRing rotary stages was optimized to minimize stage height. The low profile of the stage reduces total system working height. Cross-roller bearings are used to maximize performance with respect to wobble, moment stiffness and friction. AccuRing stage has large clear center aperture that can be used for air or wire line feed-through or beam delivery.
AccuRing utilizes direct drive three phase planar brushless motor technology. There are no brushes to replace and no gear trains or belts to maintain. Coreless magnetic design assures smooth rotation and dynamic performance.
Accurate Positioning is assured with contact-less encoder. The motor and rotary encoders are directly coupled to eliminate coupling backlash. The low inertia and zero backlash make AccuRing the ideal solution for applications requiring frequent directional changes.
|
System Performance
|
Unit |
PSR-325TJ |
Center aperture |
mm |
164 |
Outside diameter |
mm |
325 |
Stage height |
mm |
65 |
Peak Torque |
Tp (Nm) |
90 |
Continuous torque air cooling, coil 120°C |
Tc120 (Nm) |
30 |
Peak current at Tp |
Amp p rrms |
3.4 |
Continuous current at Tc |
Amp c rrms |
1.1 |
Recommended voltage (note 1) |
Uvac |
110/220 |
Max speed (note 2, 3) |
RPM |
120 |
Encoder) |
lines/rev
|
31,488 1Vpp 6,297,200 5VTTL |
Accuracy |
Arc-sec |
30 |
Repeatability | Arc-sec | 2 |
Run-out axial/radial |
micron |
8 |
Rotor Inertia | kg x m2 | 0.12 |
Stage weight |
M (Kg) |
20 |
Axial load |
M (Kg) |
500 |
Note 1: Rotary table can operate at lower voltages with lower speeds
Note 2: Max speed shown with no external torque applied
Note 3: Max speed may be limited by controller's encoder frequency input.
Sin/cos 1 Vpp and other encoder resolutions available.
Contact the factory.